AS 4100 (2020)
This Standard provides designers of steel structures with specifications for steel structural members used for load-carrying purposes in buildings and other structures.
Note: Checks are performed for the following symmetric cross sections: I-beams, Channels, Tee, Circular and Rectangular tubes, Circular and Rectangular bars.
To add the Standard execute
from the ribbon:Press to Set Standard Custom Settings
According to the calculation procedure, Beam Length for Y and Z direction is required. Data from Beam Member Finder is used automatically. If beam members are not recognized press
Options
Residual Stresses - Tables 5.2 and 6.2.4;
Section Net Area - Net area of the cross-section (Cl 7.2), Default value = 0;
Correction Factor - Correction factor for distribution of forces (Table 7.3.2), Default value = 1;
Twist Restraint Factor - Table 5.6.3(A), Default value = 1;
Load Height Factor - Table 5.6.3(B), Default value = 1;
Lateral Rotation Restraint Factor - Table 5.6.3(C), Default value = 1;
Moment Modification Factor - Table 5.6.1 or 5.6.2, Default value = 1;
Lateral Restraint - (Cl 5.3.1), Does segment have full lateral restraint? Default value = Yes;
Section Constant - Appropriate member section constant (Table 6.3.3(A) or 6.3.3(B)), Default value = 0;
Calculate Asymmetric Shapes as Symmetric - Calculate asymmetric shapes as symmetric. Min width and thickness are used.
Constant
Capacity factors for strength limit states, Phi - Table 3.4