New features in SDC Verifier

  • Nonlinear results location in Femap 11.2 was changed. Reading results function is updated to read nonlinear results from a new location.
  • Eurocode3 update: if stress history has only one Load Group – Utilization Factor is calculated, for few Load Groups fatigue damage is also calculated;
  • Predefined checks: static stress check, average stresses, plate principal stresses, solid principal stresses;
  • Job contain 2 selections: first – for analysis in Femap, second – read results in SDC Verifier;
  • Edit Multiple Load Sets/Load Groups – interface is improved, a possibility to paste names of loads;
  • Contour plots for beams;
  • Contour Output Vector plot – display contour plot for custom output vector;
  • Stop generation of table or plot immediately;
  • Copy checks between standards;
  • Update for Free Edge tool – recognize also coincident nodes, combine free edges in groups of elements;
  • Output Vector Selector in expand/extreme tables is updated – it is possible to store selections to library;

Fixed Bugs

#FixedBugs
  • Sorting feature in report for plots and tables: by Load, by Parameter, by Selection/Section;
  • Copy structure (all items) from one check to another in report;
  • A tool that resolves an issue with connection to Femap. (Tools – Register Femap in System);
  • Requested results in Job for Custom analysis was set to default after report generation;
  • Customer in properties was not saved to file;
  • Preview functions always showed elements with thickness;
  • Automatic plot after applying buoyancy and tank load is removed;
  • Using filter in selection list instead of one item two were selected;
  • Edit Fatigue Summation check when after calculation was not possible;
  • Open as template in embed mode use wrong model file;
  • Load Selector crashed if Job contains 0 loads;
  • Orientation of Mode Table is changed: in columns modes and in rows – loads;
  • Rename parameter in check converted dependent formulas into lower case;
  • Move parameters in check cause shift in report plots when saving project;
  • Standard table description was not saved.

How Do You Want to Get Started?

Free Trial version

Explore SDC Verifier — standalone or integrated with Ansys, Femap, or Simcenter 3D. Import your models, test features, and experience automated verification in action.

Download Free Trial

Engineering Consultation

Work with our engineering experts to tackle complex structural calculations, design optimization, or certification tasks. Get the support you need for project success.

Request a Consultation

Join our newsletter

    What would you like to know more about SDC Verifier?
    Loading