New Features:
SDC Verifier
- Import Femap Neutral File, Geometry, Analysis Model, Analysis Results commands;
- Meshing Toolbox, Draw/Erase, Show Tooltips commands are available now on the toolbar;
- Rebuild Model, Deleting Mesh commands are now available on the ribbon;
- Modelling tools are added to the Tools page on the ribbon;
SDC for FEA
- Support of Modal and Eigenvalue Buckling analyses (Ansys);
- Hot Spot Stress is extended for the full element face;
Bug Fixes:
SDC Verifier
- An error appeared on importing the Femap model without having the scratch folder selected in the Preferences manually;
- Crash appeared on the Report Designer after clicking on Report Layout on the Ribbon;
- The project was not saved after importing the Femap model;
SDC for FEA
- Incorrect formula was used in F.E.M. 1.001 (3rd, 1998) standard, check ‘3..Fatigue Summation’, parameter ‘Summed Damage’;
- Incorrect formulas were used in EN 1993-1-8 (2005) Connections standard, check ‘2..Limits’, parameters: ‘Is Chord Width Class 1 or 2’ and ‘Is Chord Width Class 1’;
- Incorrect formulas were used in FKM (6th, 2012) standard when calculating non-welded solid weld parts in checks: ‘3..Fatigue (constant amplitude stress spectrum)’, ‘4..Fatigue Summation (variable amplitude stress spectrum)’; parameters: ‘Stress amplitude 1 (Spatial stress states)’, ‘Stress amplitude 2 (Spatial stress states)’, ‘Stress amplitude 3 (Spatial stress states)’;
- Conversion of stresses at interpolation points into the weld direction was missing when calculating hot spot stresses;
- Fixed exporting to groups with the same names (Simcenter 3D);
- Fixed updating recognition tools for beam models (message was shown when the model was not changed) (Ansys);
- Fatigue Components Extreme Table:
- Crash appeared when there were no Fatigue Groups created in the project;
- Fixed filtering logic;
- The title of the table was automatically replaced with the default title when opening the table for editing;
- Only selected rows were copied to the clipboard instead of the whole table;
- Plate Property had incorrect parameters after running optimization tool for Plate Buckling Check (Femap);
- Variable Stress_Gradient.X (same for all directions) returned incorrect result;
- Predefined Load Cases did not work for Job of Jobs;
- Crash appeared on pressing Ok button in Import Shapes without having selected any shapes to import;
- An error appeared on loading the logo after loading Engineer details on creating a new project;
- Crash appeared in Select Load Window when no job was selected;
- The chosen unit system was not taken into account in Extreme and Flow tables Custom Check Table;
- Wrong message appeared when filling the Expand/Extreme table for “Reaction Force” category in case of absence of the Reaction Force results;
- The “Failed to attach load results” message appeared in Results Manager when trying to select custom or “Set as Default” Result Folder;
- Centroid result option in Solid Stress was not copied on job being copied;
- Report Designer:
- Crash appeared on Components Extreme Table open for Edit after clicking the Select Load button;
- Multiple Plots with the same parameters were created after selecting multiple parameters on adding;
- Report items could not be generated any more once the generation of the report was terminated;
- The Individual Loads Content item could not be generated when it was added from the context menu (Ansys);