What’s New in SDC Verifier 2024 R1.1

New Features in SDC Verifier:

  • Unlocked geometry commands for all license levels; 
  • Locked mesh commands depending on license level; 
  • Limited elemental results calculations (Stresses, GP Forces etc.) depending on license level; 
  • Added Stitch command; 

Bug Fixes in SDC Verifier:

  • Crash appeared when editing items in Report Designer; 
  • Software did not respond when exporting recognition items to groups; 
  • Group with Id = 0 was created when exporting components to groups; 
  • Could not install the software on machines that did not have Microsoft Visual C++ Redistributable installed; 

Bug Fixes in SDC for FEA:

  • Fixed formula of parameter ‘Utilization factor’ in checks ‘3..Fatigue (constant amplitude stress spectrum)’, ‘4..Fatigue Summation (variable amplitude stress spectrum)’ of FKM (6th, 2012) standard; 
  • Fixed formulas of Eurocode3 Welds 1D (EN1993-1-8, 2005): 
    • Parameters ‘Normal Stress’ and ‘OP Shear Stress‘ in check ‘4..Stresses P1’; 
    • Parameters ‘Normal Stress’, ‘OP Shear Stress‘, ‘IP Shear Stress’ in check ‘5..Stresses P2’; 
    • Parameters ‘Normal Stress’ and ‘IP Shear Stress‘ in check ‘6..Stresses P3’; 
    • Parameters ‘Normal Stress’ and ‘IP Shear Stress‘ in check ‘7..Stresses P4’; 
  • Fixed formula of parameter ‘Uf14’ in check ‘6..Overall’ of API RP 2A-WSD (21st, 2007) standard; 
  • Fixed formulas of parameters ‘Sigma_E’, ‘Tau_C’, ‘Uf_1’, ‘Uf_2’ , ‘Uf_3’ in check ‘1..Plate Buckling’ of BV NR615 Plate Buckling (2023) standard; 
  • Fixed formulas in check ‘2..Limits’ of  Eurocode3 Connections (EN 1993-1-8, 2005) standard so that limits from Table 7.8 are applied only to the proper connections with RHS chord and RHS or CHS braces;  
  • Fixed formula of parameter ‘Design Shear Force’ in check ‘12..Shear Check’ of AS 4100 (2020) standard; 
  • Fixed formula of parameter ‘Fb nc Major’ in check ‘5..Section I’ of AISC ASD 89 (9th, 1989) standard; 
  • Swapped bending moments were read from Simcenter 3D (SDC for Simcenter 3D); 
  • License could not be used after switching to single computer; 
  • Crash appeared when using SDC Verifier with a remote session or being inactive for some time; 
  • Message regarding the differences between the model and data in SDC Verifier appeared before analyzing the job when there are suppressed bodies in the model (SDC for Ansys); 
  • Tapered beams were not split when using Tapered Beam Tool (SDC for Femap); 
  • Incorrect reference points were set in the cross section in Femap when creating it from the shape library (SDC for Femap); 
  • Crash appeared when editing plate in Panel Finder if the direction was not recognized automatically; 
  • Engineer/customer details were not updated after editing first page item in Report Designer; 
  • Crash appeared after changing parameters to replacements in checks and editing tables afterwards in Report Designer; 
  • Page breaks were always set after copying items under the custom folder in Report Designer; 
  • Crash appeared when dragging items in Report Designer; 
  • Could not use libraries on machines that did not have Microsoft Visual C++ Redistributable installed;