New features in SDC Verifier:
- Now compatible with Ansys 2025 R1, Simcenter 3D 2412 and Femap 2412. SDC Verifier supports model import of Femap 2412.
- New account based licensing and personal cabinet.
- L-shapes added in calculations of Eurocode3 Members (EN 1993-1-1, 2005) and AISC 360-22 Members (2022) standards.
- New Standards:
- DNV RP-C203 Fatigue (2024);
- LR CSR Plate Buckling (2024);
- IACS UR S35 Plate Buckling (2023).
![]() | |
![]() | ![]() |
- Added Stress on Element option in BV NR615 Plate Buckling (2023), Eurocode3 Plate Buckling (EN 1993-1-5, 2006), DNV CG-0128 Plate Buckling (2015), DNV CG-0128 Plate Buckling (2023) standards;
- Shortcuts for main window and report designer:
- Recognition of stiffeners modeled as plates in Panel Finder;
- Improved performance of calculations of fatigue standards with turned off option to use hot spot stresses;
- Read GP force results from mid-side nodes and included them in the Weld Summation tool;
- Added possibility to run SDC for Ansys for standalone Mechanical (without Workbench);
- Added Mass Tuner tool (SDC for Femap, SDC Verifier);
- Display node ids in Tables of the Job for each point of interest;
Bug Fixes:
- EN 13001 Weld Strength check did not include bending stresses in calculations that led to underestimated results for some loads;
- Fixed formulas of parameters ‘Y shear’ and ‘Z shear’ in check ‘8..Axial Strength s’ in AISC 360-22 Members (2022) standard;
- Fixed formula of parameter ‘Shear resistance per shear plane’ in checks ‘3..Category A and D. Bearing type (non-preloaded)’, ‘5..Category B and E. Slip-resistance at serviceability (Preloaded)’, ‘6..Category C and E. Slip-resistant at ultimate (Preloaded)’ in Eurocode3 Bolts (EN 1993-1-8, 2005) standard;
- It was not possible to run Normal modes analysis without loads (SDC for Femap, SDC Verifier);
- Failed to create model via File-to-Model and Parametric Crane (SDC for Femap, SDC Verifier);
- Model could not be analyzed after converting rigids to active beam (SDC for Femap, SDC Verifier);
- Incorrect deformation was displayed in the model after plotting (SDC for Simcenter 3D);
- Custom Sections were not recognized in Panel Finder (SDC Verifier);
- Sizes of chord/braces were recognized incorrectly in I-beam, RHS and Combined connection types if elements were oriented differently;
- Incorrect number of Individual Loads were added when using Harmonic Response analysis (SDC for Ansys);
- Default air density value was always in metric unit system in Wind Load;
- Weld Strength checks results were not cleared after editing weld sizes in the table in Weld Finder;
- Favourable and Unfavourable values are switched in calculation of dynamic factors in Predefined Load cases;
- Values with wrong precision were applied in characteristic after editing;
- Incorrect properties were read for general shapes if they were modified in Femap after updating the model (SDC for Femap);
- Peak Finder tables were not sorted by view in Report Designer;
- Units were empty in Material window if custom model unit system was used;
- Incorrect unit system conversion was applied in Peak Finder Table;
- Arrows where not shown in pressure loads in Mechanical for negative values (SDC for Ansys);
- FEM Loads were not correctly synchronized with Mechanical after copying wind load (SDC for Ansys);
- Crash appeared when plotting Expand Graph (SDC Verifier);
- Legend Format was not taken into account when plotting (SDC for Ansys, SDC for Simcenter 3D);
- Main window was blocked after crash and reopening recovered project (SDC Verifier);
- Values were displayed in display unit system instead of model unit system in report property item;